{"id":21405,"date":"2026-09-28T13:52:11","date_gmt":"2026-09-28T05:52:11","guid":{"rendered":"https:\/\/sinocleansky.com\/?post_type=product&#038;p=21405"},"modified":"2026-10-29T11:16:23","modified_gmt":"2026-10-29T03:16:23","slug":"offshore-cryogenic-tank-containers-t75","status":"publish","type":"product","link":"https:\/\/sinocleansky.com\/es\/product\/offshore-cryogenic-tank-containers-t75\/","title":{"rendered":"DNV Offshore Cryogenic Tank Containers (T75)"},"content":{"rendered":"<p class=\"wp-block-paragraph\"><br>DNV 2.7-1 offshore cryogenic tank containers (T75), 10ft &amp; 15ft, 7\u201311.5 m\u00b3 for LIN, LOX &amp; LAr. ASME U-stamp, Lloyd&#8217;s Register certified. Request a quote.<\/p>","protected":false},"featured_media":21407,"parent":0,"template":"","meta":{"_acf_changed":false},"application":[784],"category-type":[783,782,780],"capacity":[740,743],"certifications":[867,771,895,772,774,868,775,869,892],"energy":[],"medium-industrial-gas":[845,846,850],"industrial-gas-equipment":[],"inspection-agency":[844],"material":[769],"product-category":[726],"products":[873,905,904],"related-products-group":[890],"working-pressure-range":[836],"class_list":["post-21405","product","type-product","status-publish","has-post-thumbnail","hentry","application-welding-and-cutting","category-type-application","category-type-industrial-gas-equipment","category-type-products","capacity-10m-100m","capacity-5-000l-10-000l-10m","certifications-adr","certifications-asme","certifications-dnv","certifications-dot","certifications-gb","certifications-imdg","certifications-iso","certifications-rid","certifications-tir","medium-industrial-gas-argon-ar","medium-industrial-gas-nitrogen-n2","medium-industrial-gas-oxygen-o2","inspection-agency-lloyds-register-lrs","material-steel","product-category-cryogenic-series","products-bulk-gases-equipment","products-cryogenic-liquid-gas-iso-tank-t75","products-iso-tank-containers","related-products-group-bulk-gases-group","working-pressure-range-low-pressure-3-mpa"],"acf":{"description_summary":"<ul>\r\n \t<li><span style=\"font-size: 12pt;\"><b>DNV2.7 -1 certificates in the box. <\/b>Every unit ships with its <b>Lloyd's Register construction and initial inspection certificates.<\/b><\/span><\/li>\r\n \t<li><span style=\"font-size: 12pt;\"><b>Built for offshore lifting. <\/b>Four lifting lugs with <b>28 mm shackles<\/b>, proof-tested at <b>5 \u00d7 rated load<\/b> (up to 40,000 kg), enhancement factor 1.254\u20131.4394 \u2014 engineered for repeated offshore lifts.<\/span><\/li>\r\n \t<li><span style=\"font-size: 12pt;\"><b>Cold that stays in. <\/b>High-vacuum multilayer insulation with static evaporation as low as <strong>0.<\/strong><strong>44 %\/day.<\/strong><\/span><\/li>\r\n \t<li><span style=\"font-size: 12pt;\"><b>ASME U-stamped inner vessel.<\/b> Design temperature down to <b>-196\u00b0C<\/b>, manufactured to ASME Section VIII Div.1 with Code Stamp.<\/span><\/li>\r\n \t<li><span style=\"font-size: 12pt;\"><b>Drops into any logistics chain. <\/b>Standard 10ft \/ 15ft ISO footprint with CSC, IMDG, ADR\/RID, TIR and USDOT approval \u2014 sea, road and rail in one box.<\/span><\/li>\r\n<\/ul>","image_gallery":[21407,21425,21424,21408,21409,21410,21406],"description":"<span data-font-family=\"\u5b8b\u4f53\">SinoCleansky offshore cryogenic tank containers (T75 UN portable tanks) in 10ft and 15ft, <\/span><b><span data-font-family=\"\u5b8b\u4f53\">double-certified to DNV 2.7-1 and Lloyd's Register<\/span><\/b><span data-font-family=\"\u5b8b\u4f53\">, delivering LIN, LOX and LAr wherever the job goes offshore.<\/span>\r\n\r\n<span data-font-family=\"\u5b8b\u4f53\">This product combine a <\/span><b><span data-font-family=\"\u5b8b\u4f53\">UN Portable Tank T75 vessel with a DNV 2.7-1 offshore frame<\/span><\/b><span data-font-family=\"\u5b8b\u4f53\"> in two sizes: <\/span><b><span data-font-family=\"\u5b8b\u4f53\">10ft (7.0 \/ 8.0 m\u00b3 effective) and 15ft (11.5 m\u00b3)<\/span><\/b><span data-font-family=\"\u5b8b\u4f53\">, rated to 0.8 MPa working pressure with high-vacuum multilayer insulation. The vessel is built to ASME Section VIII Div.1 with Code Stamp and the frame to<strong> DNV 2.7-1 \/ ISO 10855<\/strong> \u2014 engineered for offshore platforms, marine projects and multimodal transport.<\/span>\r\n\r\n<strong><i>Offshore-grade lifting safety<\/i><\/strong>\r\n\r\n<span data-font-family=\"\u5b8b\u4f53\">The frame is designed and built to DNV 2.7-1 (offshore containers) and ISO 10855, with four lifting lugs on 28 mm shackles. Each design is proof-tested at 2.5 times rated load (28,500 kg for the 7 m\u00b3 type, 40,000 kg for the 8 m\u00b3 type) with dynamic enhancement factors of 1.254\u20131.4394 and lifting angles of 30\u00b0\u201345\u00b0 \u2014 built for repeated offshore handling.<\/span>\r\n\r\n<i><span data-font-family=\"\u5b8b\u4f53\"><strong>Unmatched cold retention<\/strong><\/span><\/i>\r\n\r\n<span data-font-family=\"\u5b8b\u4f53\">High-vacuum multilayer insulation holds static evaporation to 0.44\u20130.57 %\/day depending on media, with a 5-year vacuum life and 15-year design life. A re-evacuation port allows vacuum restoration on site \u2014 no return to the factory needed.<\/span>\r\n\r\n<strong><i>Fully certified, globally compliant<\/i><\/strong>\r\n\r\n<span data-font-family=\"\u5b8b\u4f53\">The inner vessel is manufactured to ASME VIII Div.1 with Code Stamp. Every unit carries Lloyd's Register construction and initial inspection certificates, complying with <strong>DNV-ST-E2711<\/strong>, ISO 10855, CSC, IMDG, ADR\/RID, TIR, USDOT (CFR49) and IMO MSC\/Circ.860.<\/span>\r\n\r\n<strong><i> One tank, multiple gases<\/i><\/strong>\r\n\r\n<span data-font-family=\"\u5b8b\u4f53\">Configurable for LIN, LOX and LAr (UN1977 \/ UN1073 \/ UN1951). Inner vessel and piping are cleaned for oxygen service, and valves, pressure-building circuits and vaporizers are tailored per medium for fast reconfiguration between jobs.<\/span>\r\n\r\n<strong><i>Full lifecycle support<\/i><\/strong>\r\n\r\n<span data-font-family=\"\u5b8b\u4f53\">Each tank ships with the inner vessel nitrogen-purged and 100% vacuum-tested, together with construction and inspection certificates and full documentation. Safety valves and cryogenic components are available at preferential prices throughout the 15-year design life.<\/span>\r\n\r\n<strong><i>Typical applications:<\/i><\/strong>\r\n<ul>\r\n \t<li><span data-font-family=\"\u5b8b\u4f53\">LIN supply for offshore oil &amp; gas platforms and FPSOs \u2014 well kill, pressure testing and purging.<\/span><\/li>\r\n \t<li><span data-font-family=\"\u5b8b\u4f53\">On-site storage and rotation of welding shield and purge gases at marine engineering and EPC construction sites.<\/span><\/li>\r\n \t<li><span data-font-family=\"\u5b8b\u4f53\">Last-mile delivery of cryogenic liquids to islands and remote sites beyond pipeline or depot coverage.<\/span><\/li>\r\n \t<li><span data-font-family=\"\u5b8b\u4f53\">Emergency backup and peak-shaving liquid supply for hospitals, electronics and metallurgy customers.<\/span><\/li>\r\n<\/ul>","description_image_paths":"","description_image_gallery":[{"description_image_gallery_list":21411},{"description_image_gallery_list":21412},{"description_image_gallery_list":21413},{"description_image_gallery_list":21414},{"description_image_gallery_list":21415},{"description_image_gallery_list":21417}],"technical_specifications":"<i><span data-font-family=\"\u5b8b\u4f53\">Parameter List<\/span><\/i>\r\n<table style=\"height: 344px; width: 100%; border-collapse: collapse; border-style: ridge;\" border=\"1\">\r\n<tbody>\r\n<tr style=\"height: 56px;\">\r\n<td style=\"width: 22.4719%; height: 56px; text-align: left;\" width=\"145\">\r\n<p style=\"text-align: center;\" data-version=\"3.0.0\" data-hash=\"de61462c444e52de5ef885af2b84bde3\"><span style=\"color: #008000;\"><strong><span style=\"font-size: 10pt;\">Item \/ Model<\/span><\/strong><\/span><\/p>\r\n<\/td>\r\n<td style=\"width: 25.8427%; height: 56px; text-align: center;\" width=\"167\"><span style=\"color: #008000;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">SCSI-7-0.8\u00a0<\/span><\/strong><\/span><\/td>\r\n<td style=\"width: 25.8427%; height: 56px; text-align: center;\" width=\"167\"><span style=\"color: #008000;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">SCSI-8-0.76<\/span><\/strong><\/span><\/td>\r\n<td style=\"width: 25.8427%; height: 56px; text-align: center;\" width=\"167\"><span style=\"color: #008000;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">SCSI-12-0.8\u00a0<\/span><\/strong><\/span><\/td>\r\n<\/tr>\r\n<tr style=\"height: 24px;\">\r\n<td style=\"width: 22.4719%; height: 24px; text-align: left;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">Size<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">10 ft<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">10 ft<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">15 ft<\/span><\/strong><\/td>\r\n<\/tr>\r\n<tr style=\"height: 24px;\">\r\n<td style=\"width: 22.4719%; height: 24px; text-align: left;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">Capacity<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">7.37m\u00b3<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">8.0m\u00b3<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">12.1m\u00b3<\/span><\/strong><\/td>\r\n<\/tr>\r\n<tr style=\"height: 24px;\">\r\n<td style=\"width: 22.4719%; height: 24px; text-align: left;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">Medium<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">LIN<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">LIN \/ LAr \/ LOX<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">LIN<\/span><\/strong><\/td>\r\n<\/tr>\r\n<tr style=\"height: 24px;\">\r\n<td style=\"width: 22.4719%; height: 24px; text-align: left;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">Working pressure<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">0.8 MPa<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">0.76 MPa<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">0.8 MPa<\/span><\/strong><\/td>\r\n<\/tr>\r\n<tr style=\"height: 24px;\">\r\n<td style=\"width: 22.4719%; height: 24px; text-align: left;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">Design temperature<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">-196\u2103 ~ +50\u2103<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">-196\u2103<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">-196\u2103 ~ +55\u2103<\/span><\/strong><\/td>\r\n<\/tr>\r\n<tr style=\"height: 24px;\">\r\n<td style=\"width: 22.4719%; height: 24px; text-align: left;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">SER<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">\u22640.57 %\/d (LIN)<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">\u22640.54 %\/d (LIN)<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">\u22640.44 %\/d (LIN)<\/span><\/strong><\/td>\r\n<\/tr>\r\n<tr style=\"height: 24px;\">\r\n<td style=\"width: 22.4719%; height: 24px; text-align: left;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">Vacuum life<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">5 years<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">5 years<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">5 years<\/span><\/strong><\/td>\r\n<\/tr>\r\n<tr style=\"height: 24px;\">\r\n<td style=\"width: 22.4719%; height: 24px; text-align: left;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">Design life<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">15 years<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">15 years<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">15 years<\/span><\/strong><\/td>\r\n<\/tr>\r\n<tr style=\"height: 24px;\">\r\n<td style=\"width: 22.4719%; height: 24px; text-align: left;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">\u00a0Tare mass\u00a0<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">\u00a05,730 kg\u00a0<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">\u00a05,750 kg\u00a0<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">\u00a08,230 kg\u00a0<\/span><\/strong><\/td>\r\n<\/tr>\r\n<tr style=\"height: 24px;\">\r\n<td style=\"width: 22.4719%; height: 24px; text-align: left;\" width=\"145\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">Payload<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; text-align: center; height: 24px;\" width=\"167\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">\u00a05,670 kg (LIN)\u00a0<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; text-align: center; height: 24px;\" width=\"167\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">\u00a06,150kg (LIN)\u00a0<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; text-align: center; height: 24px;\" width=\"167\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">\u00a09,315 kg (LIN)\u00a0<\/span><\/strong><\/td>\r\n<\/tr>\r\n<tr style=\"height: 24px;\">\r\n<td style=\"width: 22.4719%; height: 24px; text-align: left;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">\u00a0Max gross mass\u00a0<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">\u00a011,400 kg\u00a0<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">\u00a011,900 kg\u00a0<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">\u00a017,545 kg\u00a0<\/span><\/strong><\/td>\r\n<\/tr>\r\n<tr style=\"height: 24px;\">\r\n<td style=\"width: 22.4719%; height: 24px; text-align: left;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">\u00a0Dimensions\u00a0<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">\u00a02,991\u00d72,438\u00d72,591 mm\u00a0<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">\u00a02,991\u00d72,438\u00d72,591 mm\u00a0<\/span><\/strong><\/td>\r\n<td style=\"width: 25.8427%; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\" data-font-family=\"\u5b8b\u4f53\">\u00a04,584\u00d72,438\u00d72,591 mm\u00a0<\/span><\/strong><\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>","packaging_shipping":"<span data-font-family=\"\u5b8b\u4f53\">The offshore tank unit itself is a <\/span><b><span data-font-family=\"\u5b8b\u4f53\">T75 UN Portable Tank \/ DNV 2.7-1 offshore container<\/span><\/b><span data-font-family=\"\u5b8b\u4f53\"> \u2014 no secondary packaging required; it enters sea, road and rail transport as its own shipping containment.<\/span>\r\n<ul>\r\n \t<li><span data-font-family=\"\u5b8b\u4f53\">Lift only through the four lifting lugs with shackles \u226528 mm (8.5T); keep the sling angle within 30\u00b0\/45\u00b0 as stated on the certificate.<\/span><\/li>\r\n \t<li><span data-font-family=\"\u5b8b\u4f53\">On arrival, verify the LR certificate number, serial number and vacuum \/ pressure gauge readings to confirm no transport damage.<\/span><\/li>\r\n \t<li><span data-font-family=\"\u5b8b\u4f53\">Before connecting lines, check the pressure-building circuit, liquid \/ gas ports and safety valves; for first commissioning, ask SinoCleansky engineers for remote or on-site guidance.<\/span><\/li>\r\n \t<li><span data-font-family=\"\u5b8b\u4f53\">Spare safety valves, cryogenic valves and vaporizers can ship with the order on a separate pallet.<\/span><\/li>\r\n<\/ul>","packaging_image_paths":"","packaging_image_gallery":[{"packaging_image_gallery_list":21418},{"packaging_image_gallery_list":21419},{"packaging_image_gallery_list":21519}],"report_certifications_content":" Every unit ships with a Lloyd's Register offshore container construction certificate, LRQA initial inspection certificate and ASME U-stamp documentation.","report_certifications_image":[{"report_certifications_image-certification_image":21420},{"report_certifications_image-certification_image":21421},{"report_certifications_image-certification_image":21422},{"report_certifications_image-certification_image":21423}],"faq":[{"faq_-_question":"How is an offshore tank container different from a standard T75 cryogenic ISO tank?","faq_-_answer":"The difference is in the frame and lifting system: offshore tank containers are built to DNV 2.7-1 and ISO 10855 with four lifting lugs, proof-tested at 2.5 times rated load and qualified with dynamic enhancement factors of 1.254\u20131.4394 for repeated offshore lifts. A standard T75 tank follows conventional container standards and carries no offshore lifting certification.\r\n"},{"faq_-_question":"s the vacuum insulation really reliable? How much liquid is lost?","faq_-_answer":"Yes. Static evaporation rates are \u22640.44\u20130.57 %\/day depending on medium, with a 5-year vacuum life, 15-year design life and 100% factory vacuum testing (\u22640.05 Pa). A re-evacuation port lets you restore vacuum on site years later \u2014 no factory return required.\r\n"},{"faq_-_question":"What is the lead time, and which certificates come with the tank?","faq_-_answer":"Every unit ships with a Lloyd's Register offshore container construction certificate, LRQA initial inspection certificate and ASME U-stamp documentation. Standard configurations typically deliver within 60\u201390 days of order confirmation (per quotation); with certificates in hand the tank enters global sea, road and rail transport immediately.\r\n"}],"specification_image_paths":"","pdf_file_paths":null,"video_links":null,"type":"Offshore Cryogenic Tank Container T75 | SinoCleansky","material":"Steel","working_pressure":"0.76Mpa-0.8","capacity":"7.37m\u00b3-12.1m\u00b3","medium":"LIN\/LOX\/LAr","standards_certifications":"DNV-ST-E2711, ISO 10855, CSC, IMDG, ADR\/RID, TIR, USDOT (CFR49)\r\n","application_scenario":"Industrial gas"},"_links":{"self":[{"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/product\/21405","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/types\/product"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/media\/21406"},{"embeddable":true,"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/media\/21410"},{"embeddable":true,"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/media\/21409"},{"embeddable":true,"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/media\/21408"},{"embeddable":true,"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/media\/21424"},{"embeddable":true,"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/media\/21425"},{"embeddable":true,"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/media\/21407"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/media\/21407"}],"wp:attachment":[{"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/media?parent=21405"}],"wp:term":[{"taxonomy":"application","embeddable":true,"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/application?post=21405"},{"taxonomy":"category-type","embeddable":true,"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/category-type?post=21405"},{"taxonomy":"capacity","embeddable":true,"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/capacity?post=21405"},{"taxonomy":"certifications","embeddable":true,"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/certifications?post=21405"},{"taxonomy":"energy","embeddable":true,"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/energy?post=21405"},{"taxonomy":"medium-industrial-gas","embeddable":true,"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/medium-industrial-gas?post=21405"},{"taxonomy":"industrial-gas-equipment","embeddable":true,"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/industrial-gas-equipment?post=21405"},{"taxonomy":"inspection-agency","embeddable":true,"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/inspection-agency?post=21405"},{"taxonomy":"material","embeddable":true,"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/material?post=21405"},{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/product-category?post=21405"},{"taxonomy":"products","embeddable":true,"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/products?post=21405"},{"taxonomy":"related-products-group","embeddable":true,"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/related-products-group?post=21405"},{"taxonomy":"working-pressure-range","embeddable":true,"href":"https:\/\/sinocleansky.com\/es\/wp-json\/wp\/v2\/working-pressure-range?post=21405"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}