CAES-Compressed-Air Storage Jumbo Tube Container
- Capacity & peak-shaving: compact footprint, rivaling battery storage in peak-shaving capacity.
- Lightweight & flexible: 4142 ultra-light high-strength steel trims weight ~6% and boosts capacity ~11%, deployable indoor or out without heavy foundations.
- High-pressure safety: 25 MPa working pressure with relief valves and leak detection; compliant with ISO 11120 and pressure-equipment safety standards.
- Certification & traceability: ISO 11120 compliant, third-party inspected by BV / TUV / LRS, with per-tube serial traceability of material and process.
Описание
SinoCleansky Jumbo Tube cascades turns a standard container into a “compressed-air battery”
From 2 tubes to 16 tubes, maximum water volume 39.2m³
Storing compressed air at 25 MPa, more space-efficient and weatherproof than conventional storage.
From renewable curtailment and islanded micro-grids to behind-the-meter peak-shaving and industrial load-shifting, our ISO 11120-certified, third-party-inspected cascades keep power where it belongs.
One cascade, generation and load side compatible — plug and play.
CSC Approval by BV.



Технические характеристики
Jumbo Tube Cylinder-MEGC Parameter
| Item / Model | SCSF8-2450-Air | SCSF9-2450-Air | SCSF10-2450-Air | SCSF11-2450-Air | SCSF12-2450-Air | SCSF15-2450-Air | SCSF16-2450-Air | SCSF12-1066-Air |
| Cylinder quantity | 8 | 9 | 10 | 11 | 12 | 15 | 16 | 12 |
| Наполнитель | Сжатый воздух | Сжатый воздух | Сжатый воздух | Сжатый воздух | Сжатый воздух | Сжатый воздух | Сжатый воздух | Сжатый воздух |
| Steel type | 4142 | 4142 | 4142 | 4142 | 4142 | 4142 | 4142 | 4142 |
| Рабочее давление | 25MPa | 25MPa | 25MPa | 25MPa | 25MPa | 25MPa | 25MPa | 25MPa |
| Cylinder Water Capacity | 2450L | 2450L | 2450L | 2450L | 2450L | 2450L | 2450L | 1066L |
| Cylinder size/mm | φ559*11580 | φ559*11580 | φ559*11580 | φ559*11580 | φ559*11580 | φ559*11580 | φ559*11580 | φ559*5400 |
| Wall thickness/mm | 14.8 | 14.8 | 14.8 | 14.8 | 14.8 | 14.8 | 14.8 | 14.8 |
| Working temperature | -50℃~65℃ | -50℃~65℃ | -50℃~65℃ | -50℃~65℃ | -50℃~65℃ | -50℃~65℃ | -50℃~65℃ | -50℃~65℃ |
| Equipment weight/kg | 23,840 | 26,200 | 29,600 | 32,180 | 34,805 | 42,910 | 45,305 | 17,580 |
| Filling weight/kg | 6,320 | 7,110 | 7,900 | 8,690 | 9,480 | 11,850 | 12,640 | 4,124 |
| Total weight/kg | 30,160 | 33,310 | 37,500 | 40,870 | 44,285 | 54,760 | 57,945 | 21,704 |
| Water volume/M³ | 19.6 | 22.1 | 24.5 | 27.0 | 29.4 | 36.8 | 39.2 | 12.8 |
| Filling gas volume/Nm³ | 4,900 | 5,513 | 6,125 | 6,738 | 7,350 | 9,188 | 9,800 | 3,198 |
| Overall Dimension/(L*W*H)mm |
12192*2438*1400 (40ft skid) |
12192*2438*1890 (40ft skid) |
12192*2438*1890 (40ft skid) |
12192*2438*1890 (40ft skid) |
12192*2438*2000 (40ft skid) |
12192*2438*2591 (40ft skid) |
12192*2438*2595 (40ft skid) |
6058*2438*2000 (20ft skid) |
Упаковка и доставка
The jumbo tube cascade & container can be shipped by standard containers, open top containers, or bulk cargo based on sizes. The cylinder cascade will be delivered with special protection if in container.


Отчеты и сертификаты
Часто задаваемые вопросы
Same product family, different medium. Both use φ559 × 11,580 mm seamless steel tubes in 4142 high-strength steel with a 14.8 mm wall, rated 25 MPa at −50 ℃ to 65 ℃, built to ISO 11120. The CNG version moves natural gas; the CAES version stores compressed air for grid peak-shaving. Because air is far less dense, the same footprint holds about 75.6% of the CNG figure
Extractable work is an ideal adiabatic estimate: about 13.8 kWh per m³ of water volume. Actual electricity delivered further depends on expander efficiency and thermal management; e.g. 12-tube water capacity 29.4m³≈405(kWh)
They complement rather than replace each other. Tube-bank air storage wins on life and safety: on the order of 20 years of design life, no capacity-fade retirement, no thermal-runaway fire risk, extremely low self-discharge (hours to seasonal), and recyclable steel. Lithium is usually cheaper and more efficient for short durations up to 2–4 hours. Rule of thumb: minutes to four hours — lithium first; long duration, large capacity, long life and high safety — CAES tube banks first. Indicative round-trip efficiency: 42–55% diabatic, 60–70% adiabatic.